SYS ONLINE INGEST 6 hours ago SOURCE NHTSA · TC BUILD v0.0.29
Vehicle scope Default: all classes — narrow to retail passenger anytime
Network/ Canada/ GMC/ 2005108

GMC · Canada · High

GMC Yukon XL: Electrical

Affects GMC Yukon XL · 2000–2001 — about 9K vehicles.

The hazard

Certain vehicles were built with fuel module reservoir assemblies that contain fuel pump wires and/or connectors that may overheat under certain operating conditions. Fuel pump wires that overheat may become exposed and result in one or more conditions; 1) If the ignition circuit wire is exposed and shorts to ground, the fuel pump fuse will blow, disabling the fuel pump and causing an engine stall or no-start condition. 2) If sufficient heat is conducted to the pass-through connector, a hole in the connector may result, which may cause the Service Engine Soon light to be illuminated during the emission system diagnostics routine. Fuel vapour (and in some limited cases liquid fuel) may leak out of the fuel tank through the hole in the connector body. 3) If the ignition circuit or ground wire is exposed and shorts to the fuel level sender card wires, inaccurate fuel level readings may result. Correction: Dealers will affect repairs.

What to do

Contact your dealer; the remedy details were not included in the filing.

Critical — crash/injury risk now High — injury risk; see remedy Moderate — fix at next service Low — minor / informational